Not yet rated
(0 ratings)
From:
magehana47
Views:
1
Comments:
0
Added:
8 minutes ago
Not yet rated
(0 ratings)
From:
magehana47
Views:
1
Comments:
0
Added:
30 minutes ago
Abnormal LV motion in patient with LBBB
In this apical TTE clip, cerful review demonstrates that the septum and lateral wall have a slight delay in activation which is to be expected in this patient with left bundle branch block.
Runtime: 0m:2s
(1 ratings)
From:
drdavemd
Views:
2000
Comments:
0
Added:
168 days ago
(1 ratings)
From:
drdavemd
Views:
2447
Comments:
4
Added:
483 days ago
Not yet rated
(0 ratings)
From:
magehana47
Views:
1631
Comments:
0
Added:
307 days ago
Not yet rated
(0 ratings)
From:
magehana47
Views:
1517
Comments:
0
Added:
307 days ago
Aortic dissection in parasternal long axis TTE
Frequently, the descending aorta can be seen just behind the left atrium in the parasternal long axis view on TTE. In this case, a subtle finding is a serious one that must be detected. The linear
echodensity across the aorta is an acute dissection of the aorta.
Runtime: 0m:4s
(5 ratings)
From:
drdavemd
Views:
2772
Comments:
2
Added:
161 days ago
Aortic insufficiency in a patient with dissection
In this TTE zoom view of the aortic/mitral valves in the parasternal long axis with color doppler, you can see dramatic aortic insufficiency. Even more worriseome is the aorta, seen just behind the
left atrium. Note that the circular structure has a linear density across it, which is a dissection flap and the cause of this patient\s acute aortic insufficiency.
Runtime: 0m:3s
Not yet rated
(0 ratings)
From:
drdavemd
Views:
2058
Comments:
0
Added:
161 days ago
Aortic Valve
An excellent parasternal short axis view of the tricuspid anatomy of the normal aortic valve.
Runtime: 0m:2s
(1 ratings)
From:
drdavemd
Views:
2958
Comments:
0
Added:
540 days ago
Aortic valve bioprosthesis
In this zoom view of the aortic and mitral valves in the transthoracic parasternal long axis clip, you can see the bright spots at the base of the aortic valve which are indicative of a bioprosthesis.
The short axis clips in this patient were not helpful in evaluating the valve\s function. His mean gradient was 15, suggesting normal flow through this prosthetic valve.
Runtime: 0m:2s
Not yet rated
(0 ratings)
From:
drdavemd
Views:
767
Comments:
0
Added:
34 days ago
Aortic valve prolapse
Short axis view of the aortic valve showing prolapsed of the right coronary cusp, this clip is very classical .
patient has per membranous VSD
Runtime: 0m:1s
Not yet rated
(0 ratings)
From:
ALMESNED
Views:
1809
Comments:
0
Added:
348 days ago
apical VSD
apical muscular ventricular septal defect,left to right shunt.parasternal and apical views.
Runtime: 0m:24s
(1 ratings)
From:
magehana47
Views:
2364
Comments:
0
Added:
153 days ago
(2 ratings)
From:
magehana47
Views:
2801
Comments:
0
Added:
281 days ago
(1 ratings)
From:
magehana47
Views:
1773
Comments:
1
Added:
207 days ago
(1 ratings)
From:
magehana47
Views:
1988
Comments:
0
Added:
207 days ago
Not yet rated
(0 ratings)
From:
magehana47
Views:
1864
Comments:
0
Added:
120 days ago
Not yet rated
(0 ratings)
From:
magehana47
Views:
1858
Comments:
0
Added:
120 days ago
atrial septal defect1
large ostium secundum atrial septal defect (with visible long eustachian valve).apical view.
Runtime: 0m:16s
Not yet rated
(0 ratings)
From:
magehana47
Views:
1573
Comments:
0
Added:
120 days ago
atrial septal defect2
large ostium secundum atrial septal defect:parasternal with m mode recording,apical and subcostal views show the defect,the right chambers dilatation and the paradoxical septal motion.
Runtime: 0m:57s
(1 ratings)
From:
magehana47
Views:
1596
Comments:
1
Added:
120 days ago
(1 ratings)
From:
magehana47
Views:
1551
Comments:
0
Added:
101 days ago